Green Building Prep

NABCEP PVIP study guide

NABCEP PVIP, administered by NABCEP, is mapped here as 7 topic areas; the heaviest are System Design & String Sizing (46%), PV Fundamentals (27%) and NEC 690/705 Code (27%).

About this course: String sizing sinks more solar installers than anything. Let's make temperature-corrected Voc and the 156% rule a method - one calc at a time.

NABCEP PVIP at a glance

Questions
70
Time allowed
4 hours
Passing standard
scaled score ≥ 70 (NOT a raw %)
Format
70 Q (60 scored + 10 unscored pilot), multiple choice, CBT/proctored
Standard / edition
current NABCEP JTA + the NEC edition NABCEP references (DYNAMIC)
Administered by
NABCEP

Source: current NABCEP JTA + the NEC edition NABCEP references (DYNAMIC), NABCEP. Confirm current details with the exam owner before you book.

Topic areas and weights

Topic areaWeightConceptsGuide
PV Fundamentals27%3Section below
System Design & String Sizing46%3Section below
NEC 690/705 Code27%2Section below
Installation6%0Section below
Commissioning & Verification5%3Section below
Maintenance & Troubleshooting5%0Section below
Safety5%0Section below

Study plan in this course

  1. PV Fundamentals — 3 cards · free
  2. Series vs Parallel — Volts Up, Amps Up — 3 cards · free
  3. Temperature & Irradiance Effects — 3 cards · free
  4. Cold-Day Voc → Maximum String Length — 4 cards · full course
  5. MPPT Window → Minimum String Length — 3 cards · full course
  6. The 156% Rule — Conductor & OCPD Sizing — 4 cards · full course
  7. Inverter Sizing, DC/AC Ratio & Voltage Drop — 3 cards · full course
  8. Rapid Shutdown — 3 cards · full course
  9. Interconnection — The 705 120% Rule — 3 cards · full course
  10. Disconnects, Grounding, AFCI & Labeling — 4 cards · full course
  11. Mechanical: Mounting, Flashing & Loads — 3 cards · full course
  12. Commissioning Tests & Startup — 3 cards · full course
  13. Fault Diagnosis & I-V Tracing — 3 cards · full course
  14. Electrical, Fall & PPE Safety — 3 cards · full course

PV Fundamentals

PV Fundamentals carries 27% of the NABCEP PVIP blueprint used in this course, the second-largest of its 7 weighted areas. It spans 3 concepts. The course teaches it in 2 study units: Series vs Parallel — Volts Up, Amps Up and Temperature & Irradiance Effects.

What PV Fundamentals covers

  • What is the Maximum Power Point, and what are Imp and Vmp — Standard PV practice
  • How does temperature affect a module's VOLTAGE — Standard PV practice
  • How does irradiance affect current and voltage — Standard PV practice

Official references for PV Fundamentals

  • Standard PV practice

In the app this area comes with 9 memory cards and 12 module-quiz questions and is part of the free starting modules.

System Design & String Sizing

System Design & String Sizing carries 46% of the NABCEP PVIP blueprint used in this course, the largest of its 7 weighted areas. It spans 3 concepts. The course teaches it in 4 study units: Cold-Day Voc → Maximum String Length, MPPT Window → Minimum String Length, The 156% Rule — Conductor & OCPD Sizing and Inverter Sizing, DC/AC Ratio & Voltage Drop.

What System Design & String Sizing covers

  • What is the MPPT voltage window — Standard PV practice
  • What is the first 1.25 factor in PV current sizing) — NFPA 70 Article 690.8
  • What is the DC/AC ratio and a typical value — Standard PV practice

Official references for System Design & String Sizing

  • NFPA 70 Article: 690.7, 690.8, 310.15
  • Standard PV practice
  • NFPA 70 Article 210.19 Informational Note

In the app this area comes with 14 memory cards and 17 module-quiz questions in the full course.

NEC 690/705 Code

NEC 690/705 Code carries 27% of the NABCEP PVIP blueprint used in this course, the third-largest of its 7 weighted areas. It spans 2 concepts. The course teaches it in 3 study units: Rapid Shutdown, Interconnection — The 705 120% Rule and Disconnects, Grounding, AFCI & Labeling.

What NEC 690/705 Code covers

  • What is the purpose of rapid shutdown — NFPA 70 Article 690.12
  • State the NEC 705 '120% rule' for load-side interconnection. — NFPA 70 Article 705.12

Official references for NEC 690/705 Code

  • NFPA 70 Article: 690.12, 705.12, 705.11, 690.13, 690.43, 690.11, 690.56

In the app this area comes with 10 memory cards and 11 module-quiz questions in the full course.

Installation

Installation carries 6% of the NABCEP PVIP blueprint used in this course, the 4th-largest of its 7 weighted areas. The course teaches it in 1 study unit: Mechanical: Mounting, Flashing & Loads.

Official references for Installation

  • Standard PV practice
  • NFPA 70 Article: 690.31

In the app this area comes with 3 memory cards and 3 module-quiz questions in the full course.

Commissioning & Verification

Commissioning & Verification carries 5% of the NABCEP PVIP blueprint used in this course, the 5th-largest of its 7 weighted areas. It spans 3 concepts. The course teaches it in 1 study unit: Commissioning Tests & Startup.

What Commissioning & Verification covers

  • Which electrical measurements verify a string before inverter startup — Standard PV practice
  • Why compare measured values to TEMPERATURE-corrected expected values — Standard PV practice
  • What documentation should commissioning produce — NABCEP PV Installation Professional Job Task Analysis

Official references for Commissioning & Verification

  • Standard PV practice
  • NABCEP PV Installation Professional Job Task Analysis

In the app this area comes with 3 memory cards and 3 module-quiz questions in the full course.

Maintenance & Troubleshooting

Maintenance & Troubleshooting carries 5% of the NABCEP PVIP blueprint used in this course, the 6th-largest of its 7 weighted areas. The course teaches it in 1 study unit: Fault Diagnosis & I-V Tracing.

Official references for Maintenance & Troubleshooting

  • Standard PV practice
  • NABCEP PV Installation Professional Job Task Analysis

In the app this area comes with 3 memory cards and 3 module-quiz questions in the full course.

Safety

Safety carries 5% of the NABCEP PVIP blueprint used in this course, the 7th-largest of its 7 weighted areas. The course teaches it in 1 study unit: Electrical, Fall & PPE Safety.

Official references for Safety

  • Standard PV practice

In the app this area comes with 3 memory cards and 3 module-quiz questions in the full course.

Official references

  • NABCEP PV Installation Professional Job Task Analysis
  • Standard PV practice
  • NFPA 70 Article: 690.7, 690.8, 310.15, 690.12, 705.12, 705.11, 690.13, 690.43, 690.11, 690.56, 690.31
  • NFPA 70 Article 210.19 Informational Note
  • NFPA: 70

Start the free NABCEP PVIP modules → · Pricing · FAQ