NABCEP PVIP study guide
NABCEP PVIP, administered by NABCEP, is mapped here as 7 topic areas; the heaviest are System Design & String Sizing (46%), PV Fundamentals (27%) and NEC 690/705 Code (27%).
About this course: String sizing sinks more solar installers than anything. Let's make temperature-corrected Voc and the 156% rule a method - one calc at a time.
NABCEP PVIP at a glance
- Questions
- 70
- Time allowed
- 4 hours
- Passing standard
- scaled score ≥ 70 (NOT a raw %)
- Format
- 70 Q (60 scored + 10 unscored pilot), multiple choice, CBT/proctored
- Standard / edition
- current NABCEP JTA + the NEC edition NABCEP references (DYNAMIC)
- Administered by
- NABCEP
Source: current NABCEP JTA + the NEC edition NABCEP references (DYNAMIC), NABCEP. Confirm current details with the exam owner before you book.
Topic areas and weights
| Topic area | Weight | Concepts | Guide |
|---|---|---|---|
| PV Fundamentals | 27% | 3 | Section below |
| System Design & String Sizing | 46% | 3 | Section below |
| NEC 690/705 Code | 27% | 2 | Section below |
| Installation | 6% | 0 | Section below |
| Commissioning & Verification | 5% | 3 | Section below |
| Maintenance & Troubleshooting | 5% | 0 | Section below |
| Safety | 5% | 0 | Section below |
Study plan in this course
- PV Fundamentals — 3 cards · free
- Series vs Parallel — Volts Up, Amps Up — 3 cards · free
- Temperature & Irradiance Effects — 3 cards · free
- Cold-Day Voc → Maximum String Length — 4 cards · full course
- MPPT Window → Minimum String Length — 3 cards · full course
- The 156% Rule — Conductor & OCPD Sizing — 4 cards · full course
- Inverter Sizing, DC/AC Ratio & Voltage Drop — 3 cards · full course
- Rapid Shutdown — 3 cards · full course
- Interconnection — The 705 120% Rule — 3 cards · full course
- Disconnects, Grounding, AFCI & Labeling — 4 cards · full course
- Mechanical: Mounting, Flashing & Loads — 3 cards · full course
- Commissioning Tests & Startup — 3 cards · full course
- Fault Diagnosis & I-V Tracing — 3 cards · full course
- Electrical, Fall & PPE Safety — 3 cards · full course
PV Fundamentals
PV Fundamentals carries 27% of the NABCEP PVIP blueprint used in this course, the second-largest of its 7 weighted areas. It spans 3 concepts. The course teaches it in 2 study units: Series vs Parallel — Volts Up, Amps Up and Temperature & Irradiance Effects.
What PV Fundamentals covers
- What is the Maximum Power Point, and what are Imp and Vmp — Standard PV practice
- How does temperature affect a module's VOLTAGE — Standard PV practice
- How does irradiance affect current and voltage — Standard PV practice
Official references for PV Fundamentals
- Standard PV practice
In the app this area comes with 9 memory cards and 12 module-quiz questions and is part of the free starting modules.
System Design & String Sizing
System Design & String Sizing carries 46% of the NABCEP PVIP blueprint used in this course, the largest of its 7 weighted areas. It spans 3 concepts. The course teaches it in 4 study units: Cold-Day Voc → Maximum String Length, MPPT Window → Minimum String Length, The 156% Rule — Conductor & OCPD Sizing and Inverter Sizing, DC/AC Ratio & Voltage Drop.
What System Design & String Sizing covers
- What is the MPPT voltage window — Standard PV practice
- What is the first 1.25 factor in PV current sizing) — NFPA 70 Article 690.8
- What is the DC/AC ratio and a typical value — Standard PV practice
Official references for System Design & String Sizing
- NFPA 70 Article: 690.7, 690.8, 310.15
- Standard PV practice
- NFPA 70 Article 210.19 Informational Note
In the app this area comes with 14 memory cards and 17 module-quiz questions in the full course.
NEC 690/705 Code
NEC 690/705 Code carries 27% of the NABCEP PVIP blueprint used in this course, the third-largest of its 7 weighted areas. It spans 2 concepts. The course teaches it in 3 study units: Rapid Shutdown, Interconnection — The 705 120% Rule and Disconnects, Grounding, AFCI & Labeling.
What NEC 690/705 Code covers
- What is the purpose of rapid shutdown — NFPA 70 Article 690.12
- State the NEC 705 '120% rule' for load-side interconnection. — NFPA 70 Article 705.12
Official references for NEC 690/705 Code
- NFPA 70 Article: 690.12, 705.12, 705.11, 690.13, 690.43, 690.11, 690.56
In the app this area comes with 10 memory cards and 11 module-quiz questions in the full course.
Installation
Installation carries 6% of the NABCEP PVIP blueprint used in this course, the 4th-largest of its 7 weighted areas. The course teaches it in 1 study unit: Mechanical: Mounting, Flashing & Loads.
Official references for Installation
- Standard PV practice
- NFPA 70 Article: 690.31
In the app this area comes with 3 memory cards and 3 module-quiz questions in the full course.
Commissioning & Verification
Commissioning & Verification carries 5% of the NABCEP PVIP blueprint used in this course, the 5th-largest of its 7 weighted areas. It spans 3 concepts. The course teaches it in 1 study unit: Commissioning Tests & Startup.
What Commissioning & Verification covers
- Which electrical measurements verify a string before inverter startup — Standard PV practice
- Why compare measured values to TEMPERATURE-corrected expected values — Standard PV practice
- What documentation should commissioning produce — NABCEP PV Installation Professional Job Task Analysis
Official references for Commissioning & Verification
- Standard PV practice
- NABCEP PV Installation Professional Job Task Analysis
In the app this area comes with 3 memory cards and 3 module-quiz questions in the full course.
Maintenance & Troubleshooting
Maintenance & Troubleshooting carries 5% of the NABCEP PVIP blueprint used in this course, the 6th-largest of its 7 weighted areas. The course teaches it in 1 study unit: Fault Diagnosis & I-V Tracing.
Official references for Maintenance & Troubleshooting
- Standard PV practice
- NABCEP PV Installation Professional Job Task Analysis
In the app this area comes with 3 memory cards and 3 module-quiz questions in the full course.
Safety
Safety carries 5% of the NABCEP PVIP blueprint used in this course, the 7th-largest of its 7 weighted areas. The course teaches it in 1 study unit: Electrical, Fall & PPE Safety.
Official references for Safety
- Standard PV practice
In the app this area comes with 3 memory cards and 3 module-quiz questions in the full course.
Official references
- NABCEP PV Installation Professional Job Task Analysis
- Standard PV practice
- NFPA 70 Article: 690.7, 690.8, 310.15, 690.12, 705.12, 705.11, 690.13, 690.43, 690.11, 690.56, 690.31
- NFPA 70 Article 210.19 Informational Note
- NFPA: 70